Ground Fault Protective Systems and Parts
GFM041X071 Instrument Transformer Ground Faulr Sensor
GROUND FAULT SENSOR, 6 TO 30 A, RECT. GROUNG FAULT CT
GFM4 GROUND PROTECTIVE DEVICE BY EATON, CUTLER HAMMER OR WESTINGHOUSE
WESTINGHOUSE GROUND FAULT PROTECTIVE DEVICE CAT# GFM4
GFM425 Ground Fault Sensor by Instrument Transformers
INSTURMENT TRANSFORMER INC. GROUND FAULT SENSOR 5 TO 18 AMP CAT# GFM 425
GFM4A by Eaton, Cutler Hammer or Westinghouse
GROUND FAULT PROTECTIVE DEVICE CLASS I PROTECTED CIRCUIT: 600 VOLTS MAX. 50/60 HERTZ 100,000 AMPS 6 CYCLES USE ONLY WITH FLUX TRANSFER SHUNT TRIP DEVICE
GFMP10 Ground Fault Protector by Eaton, Cutler-Hammer or Westinghouse
GROUND FAULT PROTECTOR RATING PLUG 10 AMPS. FOR USE WITH GFM2 OR GFM4 RELAY
GFMP100 Ground Fault Protector by Eaton, Cutler-Hammer or Westinghouse
GROUND FAULT PROTECTOR RATING PLUG 100 AMPS. FOR USE WITH GFM2 OR GFM4 RELAY
GFMP25 Ground Fault Protector by Eaton, Cutler-Hammer or Westinghouse
GROUND FAULT PROTECTOR RATING PLUG 25 AMPS. FOR USE WITH GFM2 OR GFM4 RELAY
GFMP50 Ground Fault Protector by Eaton, Cutler-Hammer or Westinghouse
GROUND FAULT PROTECTOR RATING PLUG 50 AMPS. FOR USE WITH GFM2 OR GFM4 RELAY
GFMP75 Ground Fault Protector by Eaton, Cutler-Hammer or Westinghouse
GROUND FAULT PROTECTOR RATING PLUG 75 AMPS. FOR USE WITH GFM2 OR GFM4 RELAY
GFR-1 Relay by Boltswitch
BOLTSWITCH GROUND FAULT RELAY CLASS I VOLTAGE 120 VAC 50/60 HZ CURRENT 0.0078 AMPS OUTPUT CONTACT 120 VAC 50/60 HZ INRUSH 10 AMPS CONTINUOUS 3 AMPS CAT# GFR-1
GFR60E1 Ground Fault Reset by Eaton, Cutler Hammer or Westinghouse
EATON GROUND FAULT RESET ELEC RESET WITH INTERLOCK 5/60A CAT# GFR60E1 STYLE# 1293C47G01
GFRT-11 Ground Fault Relay Primary Trip
GROUND FAULT RELAY PRIMARY TRIP CURRENT ADJUSTABLE INSTANTANEOUS TO 36 HZ ADJUSTABLE DELAY OUTPUT CONTACT RATING 10A/250 VAC - 0.5A/125 VDC CAT# GFRT-11 STYLE# GFRT-11
GFRT-12 Ground Fault Relay Primary Trip
GROUND FAULT RELAY PRIMARY TRIP CURRENT ADJUSTABLE INSTANTANEOUS TO 36 HZ ADJUSTABLE DELAY OUTPUT CONTACT RATING 10 A/250 VAC - 0.5 A /125 VAC CAT# GFRT-12 STYLE# GFRT-12
GFRTP Relay by Eaton, Cutler Hammer or Westinghouse
WESTINGHOUSE GROUND FAULT TEST PANEL CAT# GFRTP STYLE# 1276C40G01
GFS10X30 Ground Fault Sensor by Boltswitch
BOLTSWITCH GROUND FAULT SENSOR CAT # GFS10X30 OR GFS-10X30
GLR-12S Ground Relay by FPE
F P E CLASS 1 GROUND RELAY 600 VAC 50 KA TIME DELAY 0.1-1 TRIP AMPS X-100 1-12 CONTACT RATING 4 AMPS CONTINUOUS 120 VAC 12 AMPS INRUSH CAT# GLR-12S
GP-200B Ground Fault Relay by Square D
GROUND FAULT RELAY TYPE GP SERIES 2 CLASS I DELAY CURVE: B 600 VAC MAX. MINIUM OUTPUT: 0.20 AMP 21 VAC FOR 0.25 SECOND USE WITH 24 VOLT COIL LOAD HAVING 5 VA MAX. INRUSH
GT-1327 Ground Fault Sensor by Square D
SQUARE D GROUND FAULT SENSOR 600 VAC MAX. FOR USE WITH RELAYS GP 200 SERIES 2 125 KA GC 100 SERIES 2 200 KA CAT# GT-1327
GT-1330 GROUND SENSOR BY SQUARE D
SQUARE D GROUND SENSOR 600 VAC MAX CAT# GT-1330
JGGFCT100 Current Sensor by Eaton, Cutler Hammer or Westinghouse
EATON CUTLER-HAMMER NEUTRAL CURRENT SENSOR CURRENT RATIO: 100:06 CAT# JGGFCT100 STYLE# 5721B19G07
JGGFCT160 Current Sensor by Eaton, Cutler Hammer or Westinghouse
EATON CUTLER-HAMMER NEUTRAL CURRENT SENSOR CURRENT RATIO: 160:06 CAT# JGGFCT160 STYLE# 5721B19G06
R7-13A Federal Pioneer Ground Protective Device and Sensors
GROUND PROTECTIVE DEVICE TYPE T & R GROUND CURRENT SENSORS
RZ10-21 Ground Current Sensor by Federal Pioneer
GROUND CURRENT SENSOR TYPE: RZ SENSOR MAX. GROUND CURRENT 50 KA. USE WITH FPE GROUND RELAY GLR-12S or GLR-T CONSTRUCTION: RECTANGULAR WINDOW SIZE: 10.5" X 21"
SPB8FTPA Test Panel by Eaton, Cutler-Hammer or Westinghouse
SPB POW-R BREAKER GROUND FAULT TEST PANEL THIS UNIT TO BE USED ONLY WITH SPB TRIP UNITS MARKED WITH LETTER SIFFIX FOLLOWING STYLE NO. 2610DXXGXX NP 255P392H01
SPBGFTP Test Panel by Eaton, Cutler-Hammer or Westinghouse
SYSTEM POW-R BREAKER GROUND FAULT TEST PANEL FOR USE WITH SERIES 1367D47 OR 1367D52 POW-R TRIP 7 OR 2614D39-A SERIES NP1259C21G01 N.P. 235P10H01
TGRS06 Solid State Ground Break Relay by General Electric
SOLID STATE GROUND BREAKEK RELAY INPUT POWER: 120 VOLTS AC or 125 VOLTS DC OUTPUT CIRCUITS RATED 30 AMP INRUSH FOR 0.25 SECONDS AND 5 AMP CONTINUOUS
TGS0002 Ground Break Sensor by General Electric
GROUND BREAK SENSOR MAX. CONTNUOUS NET PRIMARY CURRENT 1600 AMPS. USE ONLY WITH TYPE THP OR TGSR RELAYS AND TYPE TGMP MONITOR PANELS
TGS0005 Ground Break Sensor by General Electric
GROUND BREAK SENSOR PRIMARY CURRENT 2500 AMPS. CURRENT RATIO 800:1
TGS0008 Ground Break Sensor by General Electric
GROUND BREAK SENSOR FOR USE WITH TGSR RELAYS PRIMARY CURRENT 3000 AMPS. CURRENT RATIO 800:1
TGS0408 Ground Break Sensor by General Electric
GE GROUND BREAK SENSOR PRIMARY CURRENT 4000 AMPS CAT# TGS0408
TGS0818 Ground Break Sensor by General Electric
GENERAL ELECTRIC GROUND BREAK SENSOR MAX. CONTINUOUS NET PRIMARY CURRENT 3000 A USE ONLY WITH TYPE THP AND TGSR RELAYS AND TYPE TGSMP MONITOR PANELS CAT# TGS0818
TGSMP Monitor Panel by General Electric
GROUND BREAK SYSTEM MONITOR PANEL FOR GROUND FAULT SYSTEM USE ONLY WITH TYPE TGSR RELAYS RATING 120 VOLTS 50/60 HZ.
TGSMPA Relay by General Electric
GE GROUND BREAK MONITOR PANEL VOLTAGE RATING 120 VAC CONTROL VOLTAGE 125 VDC CAT# TGSMPA
TGSMPD Monitor Panel by General Electric
GROUND BREAK SYSTEM MONITOR PANEL CONTROL VOLTAGE 24 VDC VOLTAGE RATING 120 VAC
TGSR12 Ground Break Relay by General Electric
SOLID STATE GROUND BREAK RELAY INPUT POWER- 120VAC 0R 125VDC OUTPUT CIRCUITS RATED 30 AMPS. INRUSH FOR 0.25 SECONDS AND 5 AMPS. CONTINUOUS USE WITH GE TYPE TGS MAGNETIC SENSORS NP 266205-9
TGSR12Z Relay by General Electric
GE SOLID STATE GROUND BREAK RELAY 120 VAC 0.1-1.0 TIME DELAY SECONDS CAT# TGSR12Z
TLR-1A-100 Ground Relay by Federal Pioneer
GROUND RELAY TYPE TLR HERTZ: 60 CONTROL: SELF
TLR-1A-25 Ground Relay by Federal Pioneer
GROUND RELAY TYPE TLR HERTZ: 60 CONTROL: SELF
TSSG40 Ground Break Sensor by General Electric
GROUND FAULT NEUTRAL TRANSFORMER MOD. 2 VERSATRIP 4000 AMPS. CONTINUOUS RATING FOR USE WITH CIRCUIT BREAKER TYPE TPSS/THSS9
WCT1-120AC-1 Relay by Wilmar
WILMAR OVERCURRENT RELAY PICK-UP RANGE 0.2-1 AMPS TIME DELAY RANGE 0.5-20 SECONDS CONTROL 120 VAC CAT# WCT1-120AC-1